摘要
Classic risk quantitative analysis (QRA) and simulation utilizing computational fluid dynamics (CFD) software encounter issues such as insufficient intuitiveness and high resource costs respectively when it comes to analyzing hydrogen safety of hydrogen fuel cell vehicles (HFCV). Therefore, a risk potential field superposition analysis method by considering the leakage space of typical leaking components is proposed in this paper. The simplified leakage space is developed by analyzing the leakage distribution law and spatial characteristics of typical leaking components. In addition, the thermal radiation, overpressure, and impulse risks of hydrogen leakage and explosion in the leakage space is calculated, and a risk potential field for the hydrogen system to intuitively quantify the consequences of hydrogen leakage risk is established. Finally, the risk mitigation effect of the protective cover in the hydrogen storage tank area is evaluated. The results show that the risk value of the hydrogen storage tank area when all tanks leak simultaneously is the largest, reaching 0.913, followed by the multi-stage pressure-reducing valve area at 0.323, the safety valve area at 0.236 and the fuel cell hydrogen inlet area at 0.135. Moreover, the protective cover of the hydrogen storage tank area has reduced the impact range of overpressure risk by 81.25 % with minimal weight and cost increase.
源语言 | 英语 |
---|---|
文章编号 | 124046 |
期刊 | Renewable Energy |
卷 | 256 |
DOI | |
出版状态 | 已出版 - 1 1月 2026 |
已对外发布 | 是 |